Diesel generator "OUTDOOR" range

OUTDOOR-190YC-DIESEL- TRI-EURO 3

General technical description

GENERAL DATAS

PRP Prime Rated Power : 175 kVA/140 kW
ESP Emergency Standby Power : 188 kVA/150.4 kW
Voltage : 230-400 V
Power factor (cosΦ) : 0,8
Rotation speed : 1500 rpm

Frequency : 50 Hz
Number of phases : 3
Acoustic pressure level at 7m : < 65 dB(A)
Fuel tank autonomy at : 8 h
Fuel tank capacity : 285 L

ENGINE

Model : YC6A230-D30
Number of cylinders : 6
Governor type : Electronic
Specifications : 4 stroke cycle engine, liquid-based cooling, common rail injection
Displacement : 7.25 L
Maximum standby power at rated rotation : 171 kW
Engine starting type : Electrical 24 v 

ALTERNATOR

Amperage : 260.1 A
Technology : Brushless with electronic regulation
Voltage regulation type : Electronic
IP code : 23
Insulation class : H

CIRCUIT BREAKER

Type : Four poles thermal magnetic circuit breaker with adjustable differential switches